Bubble film machine (air cushion film machine) does not allow the screw to idling without material
Time:2018/12/29Author:adminClick:
873
Bubble film machine (air cushion film machine) produces bubble film (air cushion film) By adding different additives to the plastic material, it is possible to manufacture various special air cushion films (air cushion films) such as antistatic. Anti-static air cushion film, used to package electronic components, components, such as boards, cards, etc., can prevent static electricity and can play a role of buffering anti-vibration. The aluminum foil bubble film is generally used for the insulation of the sun block of the automobile and the heat insulation of the roof.
The bubble film machine should be assigned a special operation, and the extruder screw should not be idling without material, so as to avoid the screw and the barrel being scratched. After the shutdown, if there is stock in the barrel, before starting the machine again, the temperature of each temperature zone must be raised to the specified requirements according to the process requirements, and the temperature can be turned on for 30 minutes to be turned on. So as not to damage the machine.
The bubble film machine (air cushion film machine) is regularly inspected, and the die is thoroughly cleaned every three months. The grease is replaced for various bearings, the lubricating oil is replaced once every six months, and the whole device is once every two years. Overhaul.
5. The screw is taken out from the barrel for some reason, and should be properly handled to prevent deformation. If it is not replaced in the barrel for a long time, the screw must be vertically suspended to prevent bumps, bending and permanent deformation. The surface of the screw is coated with anti-rust oil for protection.
6. After the bubble film machine (air cushion film machine) is stopped, if there is stock in the barrel, before starting the machine again, the temperature of each temperature zone must be raised to the specified requirements according to the process requirements, and the temperature can be kept for 30 minutes. Turn on the machine, do not start the machine before the temperature does not meet the requirements, so as not to damage the machine